Before activating your connection, it's essential to verify that everything is working correctly. This page guides you through testing your setup.


Prerequisites

Before testing, make sure you have completed the following steps:

circle-info

Reminder: Keep your connection Inactive during testing. Events will still be logged, but no phone calls will be triggered and no technical emails will be sent.


Trigger a Test Event

circle-info

Recommendation: Don't just send one test event. For a complete validation, test all types of actions:

  • Delayed / Instant call β€” Trigger an intrusion or fire alarm (e.g., BA, FA)

  • Cancel β€” Arm then disarm your system to verify the cancel codes (e.g., OP, OR)

  • Technical email β€” If possible, trigger a technical event (e.g., tamper, battery trouble)

This validates that all codes in your delay rule are properly received and identified.

From an Alarm Panel

Most alarm panels have a built-in test function:

1

Access panel settings

Open your alarm panel's settings.

2

Find the test option

Look for "Test Report", "Manual Test", or "Send Test to ARC".

3

Trigger the test

Trigger the test; the panel will send a test code (usually RP β€” Automatic Test) to CallOnAlarm.

From the API

If you're using the Public API, send a test alert:

β†’ See full API documentation


Verify Events Are Received

You can check incoming events in two places:

Connection Events

In your connection's configuration page, click on the Events tab.

This view shows only events for this specific connection.

Information
Description

Code

The SIA short code received (e.g., BA, FA, RP)

Type

Category of the event

Message

Description of the event

Zone / User

Zone or channel number (for device/technical events) or user ID (for user actions like arm/disarm)

Protocol

SIA or API

Time

When the event was processed

Click Refresh to update the list.


Events Page (All Connections)

From your dashboard, click Events in the navigation bar.

This view shows events from all your connections.

Use the filters to:

  • Search by connection name, account number, code or description.


Event Log Limits

The number of events stored depends on your plan:

Plan
Events per Connection

Starter

10 events

Pro

100 events

Business

500 events

Custom

As defined in your contract

circle-info

Note: When the limit is reached, older events are automatically removed to make room for new ones. Consider upgrading if you need more historical data.


What to Check

βœ… Event Received

Verify that your test event appears in the logs. If it does, your device is correctly communicating with CallOnAlarm.

βœ… Event Code Recognition

Check that the event code is correctly identified (e.g., "BA - Burglary Alarm" rather than an unknown code).


Troubleshooting

Problem
Possible Cause
Solution

No events appear

Wrong account number

Verify the account number in your device matches your connection

No events appear

Wrong server address

Verify: sia.callonalarm.io port 5001

No events appear

Firewall blocking

Ensure outbound TCP port 5001 is allowed

Unrecognized code displayed

Manufacturer-specific code

The code will still be logged as raw data. Verify your panel is SIA DC-09 compatible

Same code appears multiple times

Panel not processing ACK correctly or manufacturer-specific behavior

In your panel settings, set transmission retries to 1


Test Complete?

Once you've verified the items below, you're ready to activate your connection.

1

Events are being received

Confirm that test events appear in the logs.

2

Events appear under the correct connection

Ensure events are logged under the intended connection/account number.

β†’ Activate your connection