Simple SIA over TCP Protocol
This document describes how to integrate your device or application with CallOnAlarm using the SIA DC-09 protocol over TCP. This is the recommended method for hardware manufacturers and IoT device developers.
Note: This low-level TCP protocol is designed for manufacturers and developers who prefer direct socket communication over HTTP. If you're looking for a simpler integration using standard HTTP requests, see the Public API documentation instead.
Simplified Integration: This guide presents a simplified implementation of the SIA DC-09 protocol. We use the SIA-DCS message format exclusively, which is the most straightforward and widely supported format. Contact ID (ADM-CID) is not covered in this documentation.
Overview
CallOnAlarm accepts alarm messages using the SIA DC-09 protocol, an industry standard used by most professional alarm panels worldwide. Your device connects via TCP, sends a formatted message, and receives an acknowledgment (ACK).
Why SIA over TCP?
Industry standard
Compatible with existing alarm infrastructure
TCP reliability
Guaranteed delivery with ACK confirmation
Low bandwidth
Minimal data transfer (~100 bytes per message)
Simple workflow
Connect, send, receive ACK, disconnect
Firewall friendly
Single outbound TCP connection
Connection Details
Host
sia.callonalarm.io
Port
5001
Protocol
TCP
Encryption
Not supported at this time due to inconsistent implementation across different manufacturers.
Connection Lifecycle
Timeouts
Server-side timeouts are subject to change. These values are provided for reference only and should not be hardcoded in your implementation.
First data
10 seconds
Must send data within 10s of connecting
Idle
60 seconds
Connection closed after 60s of inactivity
Max connection
5 minutes
Maximum duration for a single connection
Note: Client-side timeouts are at your discretion. We recommend a 5-10 second timeout for ACK reception.
Message Format
Structure
All messages follow this structure:
LF
1 byte
Line Feed character (0x0A)
CRC
4 chars
CRC-16 checksum in uppercase hex (e.g., A4FE)
LENGTH
4 chars
Content length in uppercase hex (e.g., 0052)
CONTENT
Variable
The SIA message payload
CR
1 byte
Carriage Return character (0x0D)
CRC-16 Calculation
The CRC is calculated on the CONTENT portion only, using polynomial 0x8005 (CRC-16-IBM).
C implementation:
Test Vectors
Use these examples to validate your CRC implementation before connecting to CallOnAlarm.
"SIA-DCS"0001L0#12345678[#12345678|BA001]
41 (0x0029)
0xEB87
"SIA-DCS"0042L0#12345678[#12345678|FA002]
41 (0x0029)
0x9DC1
"NULL"0001L0#12345678[]
23 (0x0017)
0x480A
"ACK"0001L0#[]
14 (0x000E)
0xE77D
Tip: If your CRC values don't match these examples, check that you're using the correct polynomial (0x8005) and that your table is properly initialized.
Message Types
SIA-DCS (Alarm Events)
The simplest format for sending alarm events.
Format:
Or with optional timestamp:
SEQ
4-digit sequence number (0001-9999)
0001
ACCOUNT
Your account number from CallOnAlarm
12345678
EVENT_CODE
2-letter SIA code
BA (Burglary Alarm)
ZONE
3-4 digit zone number
001 or 0001
TIMESTAMP
Optional. Format: HH:MM:SS,MM-DD-YYYY
12:38:20,01-30-2026
Example - Burglary Alarm on Zone 1:
Example - With timestamp (optional):
Complete message with framing:
NULL (Heartbeat)
Keep the connection alive and verify connectivity.
Format:
Example:
Note: NULL messages do not trigger alerts. Use them for periodic connectivity checks (recommended: every 30-60 seconds for persistent connections).
ACK Response
After receiving a valid message, CallOnAlarm responds with an ACK.
Format:
Example:
If you sent sequence 0001, you will receive:
Validating the ACK:
Important: Always wait for the ACK before sending the next message or closing the connection.
Complete Examples
You can test the ESP32 CallOnAlarm integration in the playground here: https://wokwi.com/projects/457058213945128961
Best Practices
Sequence Numbers
Increment the sequence number (0001-9999) for each message
Roll over from 9999 to 0001
Use the sequence to match ACKs to sent messages
Error Handling
No ACK received
Retry after 5 seconds (max 3 retries)
Connection refused
Retry after 30 seconds
Invalid ACK
Log and retry with new sequence
Timeout
Close connection, reconnect, retry
Persistent Connections
Security Recommendations
Store account numbers securely
Implement rate limiting on your device
Validate ACK responses before proceeding
Troubleshooting
Common Issues
No ACK received
CRC mismatch
Verify CRC calculation
Connection closed immediately
Invalid first byte
Ensure message starts with LF (0x0A)
ACK received but no event in dashboard
Wrong account number
Verify account number matches your connection
Timeout
Network issue
Check firewall, verify host/port
Note: CallOnAlarm always sends an ACK for valid SIA messages, even if the account number doesn't exist. The only way to confirm your integration is working correctly is to check the Events section of your connection in the dashboard.
Testing Your Integration:
Security & Rate Limiting
CallOnAlarm implements server-side protections against abuse and misconfigured devices. Ensure your implementation follows best practices to avoid being banned.
Active Protections
Please, see this IP Banned by CallOnAlarm
Avoiding Bans
CRC calculation error
Verify your CRC implementation against test vectors
Missing framing bytes
Ensure messages start with LF and end with CR
Reconnection loop
Implement exponential backoff on connection failures
Excessive NULL heartbeats
For persistent connections only: send heartbeats every 30-60 seconds (30s min, 60s max)
Design Philosophy
Buffer Overflow = Attack β Immediate ban, no tolerance
Invalid Messages = Configuration Error β 10 attempts tolerance, then 1h ban
Rapid Connections = Port Scan/Flood/Brute-force β Detection and 1h to 24h ban
Automatic Reset β A valid message resets the error counter
Important: If your device gets banned, it will be automatically unbanned after the ban duration. Check your implementation before reconnecting.
Event Codes Reference
The EVENT_CODE field uses standard SIA (Security Industry Association) codes.
Complete event codes list in the API v1 section : Event Codes Reference
Support
For integration support, contact us at:
Email: [email protected]
Documentation: https://docs.callonalarm.io
Changelog
v1.0.0 (2026-01-30)
Initial release
SIA-DCS and NULL message support
CRC-16 ASCII format
C examples (POSIX and ESP32/Arduino)